詳細介紹
產品 規格:【德國原裝,全新*】
產品 質量:【*,假一罰十】
產品 價格:【薄利多銷,行業zui低】
產品 貨期:【庫存銷售,現買現賣】
:*
;
:
廣州鴻懿電氣設備有限公司竭誠為您服務
更多產品和報價咨詢掃二維碼加我
購物需知
1、西門子產品均為密封包裝,外包裝詳見產品圖片,白色標簽上均有西門子品牌LOGO及產品訂貨號,各位買家在收到貨后,請核對型號無誤,再拆包裝
2、本公司銷售的產品一律為(原裝**假一罰十*質保一年) 本公司簽約正式的銷售合同,開具17%的增值稅發票、普通發票。
6SL3210-1PE21-8UL0
西門子產品訂貨號:6SL32101PE218UL0
西門子產品價格:168 RMB
西門子產品凈重:1.100 Kg
西門子產品承諾:質保一年,原裝*
西門子產品尺寸:270.00 x 225.00 x 85.00
概述
SINAMICS G120C, frame sizes FSAA to FSF, with Inligent Operator Panel IOP
SINAMICS G120C compact inverters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel.
SINAMICS G120C inverters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance.
優勢
- Compact design
- Side-by-side design
- High power density, low envelope dimensions
- Simple installation in the tightest space
- Low space requirement
- Use in small control cabinets, close to the machine
- Optimized parameter set
- Optimized commissioning
- Getting Started document
- BOP?2 or IOP operator panels can be used
- Integrated USB connection
- Simple and fast software parameter assignment
- Simple to use during commissioning and in operation
- Minimized training costs, existing SINAMICS know-how can be used
- High degree of service friendliness, simple maintenance
- Plug-in terminals
- Cloning function using BOP?2, IOP or memory card
- Operating hours counter for "drive on" and "motor on"
- Fast mechanical installation
- Intuitive standard commissioning
- Component of Totally Integrated Automation
- Energy-efficient, sensorless vector control
- Automatic flux reduction with V/f ECO
- Integrated energy saving computer
- Safety Integrated (STO)
- Communications versions with PROFINET / EtherNet/IP, PROFIBUS DP, USS/Modbus RTU
- Coated modules
- Operation up to an ambient temperature of 60 °C (140 °F)
設計
SINAMICS G120C is a compact converter for control cabinet mounting in IP20 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device.
The compact mechanical design and the high power density allow these devices to be installed in machine control enclosures and control cabinets for maximum space utilization. The SINAMICS G120C compact converter can be butt-mounted directly, without derating at temperatures up to 40 °C (104 °F).
SINAMICS G120C, frame size FSAA with BOP-2
SINAMICS G120C can be integrated into the widest range of applications, either using the integrated digital and analog inputs or via the integrated fieldbus interface (available in USS, Modbus RTU, PROFIBUS, PROFINET / EtherNet/IP versions). Especially the product versions with integrated PROFIBUS/PROFINET interface make full integration into the Siemens TIA family possible, therefore allowing the advantages of the seamless TIA product family to be fully utilized. SINAMICS G120C devices are preset in the factory so that they can be immediay connected to PROFIBUS and/or PROFINET fieldbus systems without parameterization.
SINAMICS G120C is also equipped with the safety function STO (Safe Torque Off) as standard, which is used to safely stop drives. As a consequence, machine manufacturers can simply comply with current machinery directives with minimum associated costs.
SINAMICS G120C can control asynchronous (induction) motors in the power range from 0.37 kW up to 132 kW (0.5 hp to 200 hp). Reliable and efficient motor operation is achieved by using state-of-the-art IGBT technology combined with vector control. The extensive range of functions integrated in the SINAMICS G120C also offers a high degree of protection for the converter and motor.
Line-side components
Line reactors
Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter.
Recommended line-side power components
Standard fuses can be used for the SINAMICS G120C. These must be dimensioned to comply with local regulations. In this chapter, you will find recommended components such as fuses and circuit breakers in compliance with IEC and UL regulations.
DC link components
Braking resistors
Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G120C. This has an integrated braking chopper (electronic switch).
Load-side power components
Output reactors
Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.
Supplementary system components
Inligent Operator Panel IOP
Graphics-based, user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120C.
Basic Operator Panel BOP-2
A 2-line display to provide support when commissioning and troubleshooting the drive. The drive can be locally controlled.
Memory card
The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediay ready for use again. The associated memory card holder is integrated in the inverter.
PC inverter connection kit 2
For controlling and commissioning an inverter directly from a PC if the STARTER commissioning tool or SINAMICS Startdrive has been installed on the PC.
Spare parts
Shield plates
A set of shield plates is included in the scope of delivery for the motor and signal cables corresponding to the frame size of the SINAMICS G120C, and can also be ordered as spare parts.
Spare parts kit
This kit comprises four I/O terminals, one RS485 terminal, two pairs of Control Unit doors (1 × PN and 1 × other communication versions) and one blanking cover.
Set of connectors
A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the SINAMICS G120C inverter.
Roof-mounted fan
A roof-mounted fan (at the top of the device) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.
Fan unit
A replacement fan (at the rear of the device; heat sink) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.
集成
Connection example for SINAMICS G120C
USS/Modbus RTU communication interface
PROFIBUS DP communication interface
PROFINET, EtherNet/IP communication interface
6SL3210-1PE21-8UL0
西門子產品訂貨號:6SL32101PE218UL0
西門子產品價格:168 RMB
西門子產品凈重:1.100 Kg
西門子產品承諾:質保一年,原裝*
西門子產品尺寸:270.00 x 225.00 x 85.00
Control Units | Power Modules degree of protection IP20 | |
---|---|---|
| PM240?2/PM240 | PM250 |
CU230P?2 | ? | ? |
CU240E?2 | ? | ? |
CU250S?2 | ? | ? |
PM240, PM240?2 and PM250 Power Modules
Rated power 1) |
| Rated output current Irated2) | PM240?2 Power Modules 3) All CUs pluggable | PM250 All CUs pluggable |
---|---|---|---|---|
kW | hp | A | Article No. | Article No. |
200 ... 240 V 1 AC/3 AC | ||||
0.55 | 0.75 | 3.2 | 6SL3210-1PB13-0?L0 | – |
0.75 | 1 | 4.2 | 6SL321?-1PB13-8?L0 | – |
1.1 | 1.5 | 6 | 6SL3210-1PB15-5?L0 | – |
1.5 | 2 | 7.4 | 6SL3210-1PB17-4?L0 | – |
2.2 | 3 | 10.4 | 6SL321?-1PB21-0?L0 | – |
3 | 4 | 13.6 | 6SL3210-1PB21-4?L0 | – |
4 | 5 | 17.5 | 6SL321?-1PB21-8?L0 | – |
200 ... 240 V 3 AC | ||||
5.5 | 7.5 | 22 | 6SL3210-1PC22-2?L0 | – |
7.5 | 10 | 28 | 6SL3210-1PC22-8?L0 | – |
11 | 15 | 42 | 6SL3210-1PC24-2UL0 | – |
15 | 20 | 54 | 6SL3210-1PC25-4UL0 | – |
18.5 | 25 | 68 | 6SL3210-1PC26-8UL0 | – |
22 | 30 | 80 | 6SL3210-1*-0UL0 | – |
30 | 40 | 104 | 6SL3210-1PC31-1UL0 | – |
37 | 50 | 130 | 6SL3210-1PC31-3UL0 | – |
45 | 60 | 154 | 6SL3210-1PC31-6UL0 | – |
55 | 75 | 178 | 6SL3210-1PC31-8UL0 | – |
380 ... 480 V 3 AC | ||||
0.37 4) | 0.5 | 1.3 | – 4) | – |
0.55 | 0.75 | 1.7 | 6SL3210-1PE11-8?L1 | – |
0.75 | 1 | 2.2 | 6SL3210-1PE12-3?L1 | – |
1.1 | 1.5 | 3.1 | 6SL3210-1PE13-2?L1 | – |
1.5 | 2 | 4.1 | 6SL3210-1PE14-3?L1 | – |
2.2 | 3 | 5.9 | 6SL3210-1PE16-1?L1 | – |
3 | 4 | 7.7 | 6SL321?-1PE18-0?L1 | – |
4 | 5 | 10.2 | 6SL3210-1PE21-1?L0 | – |
5.5 | 7.5 | 13.2 | 6SL3210-1PE21-4?L0 | – |
7.5 | 10 | 18 | 6SL321?-1PE21-8?L0 | 6SL3225-0BE25-5AA1 |
11 | 15 | 26/25 | 6SL3210-1PE22-7?L0 | 6SL3225-0BE27-5AA1 |
15 | 20 | 32 | 6SL321?-1PE23-3?L0 | 6SL3225-0BE31-1AA1 |
18.5 | 25 | 38 | 6SL3210-1PE23-8?L0 | 6SL3225-0BE31-5?A0 |
22 | 30 | 45 | 6SL3210-1PE24-5?L0 | 6SL3225-0BE31-8?A0 |
30 | 40 | 60 | 6SL3210-1PE26-0?L0 | 6SL3225-0BE32-2?A0 |
37 | 50 | 75 | 6SL3210-1PE27-5?L0 | 6SL3225-0BE33-0?A0 |
45 | 60 | 90 | 6SL3210-1PE28-8?L0 | 6SL3225-0BE33-7?A0 |
55 | 75 | 110 | 6SL3210-1PE31-1?L0 | 6SL3225-0BE34-5?A0 |
75 | 100 | 145 | 6SL3210-1PE31-5?L0 | 6SL3225-0BE35-5?A0 |
90 | 125 | 178 | 6SL3210-1PE31-8?L0 | 6SL3225-0BE37-5?A0 |
110 | 150 | 205 | 6SL3210-1PE32-1?L0 | – |
132 | 200 | 250 | 6SL3210-1PE32-5?L0 | – |
160 3) | 250 | 302 | 6SL3224-0XE41-3UA0 | – |
200 3) | 300 | 370 | 6SL3224-0XE41-6UA0 | – |
250 3) | 400 | 477 | 6SL3224-0XE42-0UA0 | – |
500 ... 690 V 3 AC | ||||
11 | 10 | 14 | 6SL3210-1PH21-4?L0 | – |
15 | 15 | 19 | 6SL3210-1PH22-0?L0 | – |
18.5 | 20 | 23 | 6SL3210-1PH22-3?L0 | – |
22 | 25 | 27 | 6SL3210-1PH22-7?L0 | – |
30 | 30 | 35 | 6SL3210-1PH23-5?L0 | – |
37 | 40 | 42 | 6SL3210-1PH24-2?L0 | – |
45 | 50 | 52 | 6SL3210-1PH25-2?L0 | – |
55 | 60 | 62 | 6SL3210-1PH26-2?L0 | – |
75 | 75 | 80 | 6SL3210-1PH28-0?L0 | – |
90 | 100 | 100 | 6SL3210-1PH31-0?L0 | – |
110 | 100 | 115 | 6SL3210-1PH31-2?L0 | – |
132 | 125 | 142 | 6SL3210-1PH31-4?L0 | – |
Heat sink variant |
|
| ↑ |
|
Standard |
|
| 0 |
|
Push Through |
|
| 1 |
|
Integrated line filter |
|
| ↑ | ↑ |
Without | (for IT systems) |
| U | U |
Class A | (for TN systems) |
| A | A |
Class B | (for TN systems) |
| – | Integrated line filter not available, as external option only |
西門子產品訂貨號:6SL32101PE218UL0
西門子產品價格:168 RMB
西門子產品凈重:1.100 Kg
西門子產品承諾:質保一年,原裝*
西門子產品尺寸:270.00 x 225.00 x 85.00
如何將已編好的PLC程序塊導入源文件
如何將已編好的PLC程序塊導入源文件,艾特貿易網小編這里有兩種方法:
1.打開所要導入源文件的功能塊,在LAD/STL/FBD編輯窗口中選擇菜單FILE-->Generate Source...,輸入源文件名,選擇要導入的塊,點擊OK.后就可以在工程管理器里面的SOURCE項下找到剛才生成的源文件.打開即可
2.首先在工程管理器里面的SOURCE項建立一個源文件(打開SOURCE項,菜單:INSERT-->S7 SOFTWARE-->STL SOURCE).打開,菜單:INSERT-->BLOCK,在打開的界面選擇需要導入的塊.結果同上
另外給大家一個源文件示例:
在項目的SOURCE文件夾里
====================================
ORGANIZATION_BLOCK OB82
TITLE = SAFTY FOR profibus DP
// for XXXXXXXX
AUTHOR: Karl
FAMILY: SHA
NAME: Safty
VERSION: 00.11 //
KNOW_HOW_PROTECT
BEGIN
NETWORK
TITLE = <Safty Profibus-DP>
//
A M 0.1;
A I 0.1;
L S5T#10S;
SD T 7;
A T 7;
L S5T#30S;
SP T 5;
ON Q 1.1;
O M 1.0;
R T 5;
A T 5;
= Q 33.1;
= Q 33.4;
= Q 44.3;
R Q 33.2;
R Q 33.3;
R Q 33.5;
// Other networks
END_ORGANIZATION_BLOCK
你可以以此模式寫你自己的程序
=======================================
雙擊打開源文件,選Compile,然后在Blocks文件夾自動生成加密的OB82。