Control elements | | | | |
Expansions for operator control of the process | | | | |
| with emergency stop circuit interruption | without emergency stop circuit interruption | with emergency stop circuit interruption | without emergency stop circuit interruption |
| No | Yes | No | Yes |
| Yes | Yes | Yes | Yes |
Supply voltage | | | | |
Type of supply voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
Rated value (DC) | 24 V | 24 V | 24 V | 24 V |
permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V | 20.4 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
Input current | | | | |
Current consumption (rated value) | 0.4 A | 0.5 A | 0.4 A | 0.5 A |
Power | | | | |
Active power input, typ. | 10 W | 12 W | 10 W | 12 W |
Interfaces | | | | |
Interfaces/bus type | 1 x RS232, 1 x RS422, 1 x RS485 (max. 12 Mbit/s) | 1 x RS232, 1 x RS422, 1 x RS485 (max. 12 Mbit/s) | Ethernet | Ethernet |
Number of RS 485 interfaces | 1 | 1 | | |
Number of RS 422 interfaces | 1 | 1 | | |
Number of RS 232 interfaces | 1 | 1 | | |
Number of 20 mA interfaces (TTY) | 0 | 0 | | |
Industrial Ethernet | | | | |
| | | 2 x Fast Ethernet | 2 x Fast Ethernet |
| | | 6 | 6 |
Degree and class of protection | | | | |
Degree of protection acc. to EN 60529 | IP65 | IP65 | IP65 | IP65 |
Standards, approvals, certificates | | | | |
Certifications | CE, cULus, C-TICK | CE, cULus, C-TICK | CE, cULus, C-TICK | CE, cULus, C-TICK |
CE mark | Yes | Yes | Yes | Yes |
CSA approval | No | No | No | No |
UL approval | No | No | No | No |
cULus | Yes | Yes | Yes | Yes |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes |
EAC (formerly Gost-R) | No | No | No | No |
Marine approval | No | No | No | No |
Use in hazardous areas | | | | |
| No | No | No | No |
| No | No | No | No |
| No | No | No | No |
Ambient conditions | | | | |
Ambient temperature during operation | | | | |
| 0 to +50 °C | 0 to +50 °C | 0 to +50 °C | 0 to +50 °C |
| 0 °C | 0 °C | 0 °C | 0 °C |
| 50 °C | 50 °C | 50 °C | 50 °C |
Ambient temperature during storage/transportation | | | | |
| -20 °C | -20 °C | -20 °C | -20 °C |
| 70 °C | 70 °C | 70 °C | 70 °C |
Relative humidity | | | | |
| 85 % | 85 % | 85 % | 85 % |
Functionality under WinCC (TIA Portal) | | | | |
Applications/options | | | | |
| Yes | Yes | Yes | Yes |
Dimensions | | | | |
Width | 160 mm | 160 mm | 230 mm | 230 mm |
Height | 120 mm | 120 mm | 120 mm | 120 mm |
Depth | 70 mm | 70 mm | 80 mm | 80 mm |
Weights | | | | |
Weight (without packaging) | 0.35 kg | 0.4 kg | 0.45 kg | 0.5 kg |
Other | | | | |
free hotline | Yes | Yes | Yes | Yes |
Warranty period | 1 y | 1 y | 1 y | 1 y |
Usable in the following products | | | | |
| 6AV6645-0A* | 6AV6645-0A* | 6AV6645-0BA01-0AX0 | 6AV6645-0BA01-0AX0 |
| 6AV6645-0C* | 6AV6645-0C* | 6AV6645-0BB01-0AX0 | 6AV6645-0BB01-0AX0 |
| 6AV6645-0BE02-0AX0 | 6AV6645-0BE02-0AX0 | 6AV6645-0BC01-0AX0 | 6AV6645-0BC01-0AX0 |
| | | 6AV6645-0BE02-0AX0 | 6AV6645-0BE02-0AX0 |
| | | 6AV6645-0C* | 6AV6645-0C* |