General information | |
HW functional status | E03 |
Firmware version | V1.1.x |
Product function | |
| Yes; I&M0 to I&M3 |
Engineering with | |
| STEP 7 V15 or higher |
| From V5.5 SP4 Hotfix 3 |
| GSD as of Revision 5 |
| GSDML V2.3.1 |
Supply voltage | |
Load voltage 1L+ | |
| 24 V |
| 20.4 V |
| 28.8 V |
| Yes |
Load voltage 2L+ | |
| 24 V |
| 20.4 V |
| 28.8 V |
| Yes; against destruction; load increasing |
Input current | |
Current consumption (rated value) | 40 mA; without load |
from load voltage 1L+ (unswitched voltage) | 4 A; Maximum value |
from load voltage 2L+, max. | 4 A; Maximum value |
Encoder supply | |
Number of outputs | 4 |
24 V encoder supply | |
| Yes; per module, electronic |
| 1.4 A; Total current of all ports |
Power loss | |
Power loss, typ. | 2.6 W |
IO-Link | |
Number of ports | 4 |
| 4 |
IO-Link protocol 1.0 | Yes |
IO-Link protocol 1.1 | Yes |
Transmission rate | 4.8 kBaud (COM1); 38.4 kBaud (COM2), 230 kBaud (COM3) |
Size of process data, input per port | 32 byte |
Size of process data, input per module | 32 byte |
Size of process data, output per port | 32 byte |
Size of process data, output per module | 32 byte |
Memory size for device parameter | 2 kbyte; for each port |
Master backup | Possible with function block IO_LINK_MASTER |
Configuration without S7-PCT | Possible; autostart/manual function |
Cable length unshielded, max. | 20 m |
Operating modes | |
| Yes |
| Yes |
| Yes; max. 100 mA |
Connection of IO-Link devices | |
| Yes; via 3-core cable |
| Yes; Additional device supply: 1.6 A total current of all ports |
Interrupts/diagnostics/status information | |
Alarms | |
| Yes; Parameterizable |
Diagnostic messages | |
| Yes |
| Yes |
| Yes |
Diagnostics indication LED | |
| Yes; Green LED |
| Yes; Green/red LED |
| Yes; Green LED |
Potential separation | |
between the load voltages | Yes |
Potential separation channels | |
| No |
| Yes |
| No |
Isolation | |
Isolation tested with | 707 V DC (type test) |
Degree and class of protection | |
IP degree of protection | IP65/67 |
Standards, approvals, certificates | |
Suitable for safety-oriented group deactivation | Yes |
Highest safety class achievable in safety mode | |
| PL d |
| SIL 2 |
Ambient conditions | |
Ambient temperature during operation | |
| -25 °C |
| 55 °C |
Connection method | |
Design of electrical connection for the inputs and outputs | M12, 5-pole |
Power supply | M8, 4-pole |
ET-Connection | |
| M8, 4-pin, shielded |
Dimensions | |
Width | 30 mm |
Height | 159 mm |
Depth | 40 mm |
Weights | |
Weight, approx. | 145 g |