The Massa Ultrasonic Ranging Module is a precision electronic measurement device which includes an interface electronics moduleone or two ultrasonic transducers, depending on the model selected. The ranging module provides the OEM with a PWMLATCH output pulse, whose duration is proportional to the time required for the sound to travel between the transmitreceive transducers. The LATCH pulse width may be processed through additional circuitry for applications requiring position, level, profile, or thickness measurements.

Internally or externally triggered, target distance ultimay limits the maximum pulse repetition rate. A maximum rate of 150 Hz is possible when targets are less than one foot distant; refer to individual module specifications for rep rate limits. For internal triggering, the pulse repetition rate is set via a single external resistor.

The E-201B Series utilizes two transducers, one to transmitone to receive acoustic pulses. This arrangement allows them to be mounted side-by-side for an echo ranging application, or mounted opposing one another for high speed counting or accurate measurements at over twice the range possible with echo ranging. Two transducer echo-ranging configurations also provide shorter minimum target distances, required for certain applications.

The E-220B Series utilizes a single transducer for both sendingreceiving acoustic pulses. This arrangement is ideal for applications where a limited area is available for mounting the sensor. Minimum target distance is slightly farther than two-transducer configurations.

Optional transducer mounting brackets provide for easy adjustments to sensor alignment during installationhave been specifically designed to minimize crosstalk between paired transducers (E-201B).

Request Massa''s Application Guide To Ultrasonic Sensing for a comprehensive review of application considerations.

Applications

Ultrasonic Micrometer

Non-contact Profile Gauge

Precision Limit Switch

Thickness Unifomity Control

Precision Proximity Detection

High Speed Counting


Features

Remoy Mounted Sensors

Resolution to +/- 0.010 inches

Single Supply Operation

Low Current Drain

Internal or External Trigger

Ultrasonic Ranging Module Product Selection Guide

Individual Specifications



Model Number


E-201B/215 E-201B/150 E-220B/215 E-220B/150 E-220B/40 E-220B/26
Transducers Supplied


Two Two One One One One
Detection Range1
Echo Ranging
Opposed Alignment2


3"-24"
3"-48"
5"-60"
5"-120"
4"-24"
N/A
8"-60"
N/A
2''-20''
N/A
2''-30''
N/A
Resolution:
Instantaneous3
Averaged4



0.03"
0.2%
0.04"
0.1%
0.03"
0.2%
0.04"
0.1%
0.3"
0.1%
0.4"
0.1%
Beam Angle5,6


10 10 10 10 15,35 15,35
Transducer Frequency


215 kHz 150 kHz 215 kHz 150 kHz 40 kHz 26 kHz
Maximum Pulse Rate


150 Hz 100 Hz 150 Hz 100 Hz 25 Hz 20 Hz
Notes:
1- Nominal values at ambient temperature, pressurehumidity;
2- One transducer affixed to each of two objects, then aimed at each other;
3- Conservatively rated, improved dramatically with constant, controlled environment;
4- Percent of range; averaging processed externally, typically using a computer or PLC;
5- Total width at -3 dB points, no secondary lobes exist with /150 & /215 transducers;
6- Detachable horn supplied with /40 & /26 transducers provides smaller beam angle (required for maximum range).


General Specifications


Output Pulse Width (LATCH)1


Echo Ranging 147.5 usec per inch (or 1.77 msec per foot) of target distance


Opposed Alignment 73.75 usec per inch (or 0.89 msec per foot) of sensor separation)


External Trigger Pulse Width


Optionally Required 180 +/- 10 uSec
Digital Output (LATCH) Sink Current


N-Channel MOSFET 30 mA @ Vds=0.5 V
Voltage Requirements



Limits
Recommended 8 to 15 V DC
12 V DC
Power Requirements (Nominal)



20 mA @ 8 V DC
30 mA @ 15 V DC 160 mW
450 mW
Temperature Range2



Operating
Storage 0 to 60 C
-25 to 85 C
Humidity



Non-condensing 0 to 90%
Transducer Construction



Sealed Housing
Standard Housing /215 & /150 Models
/40 & /26 Models
Weight


Electronics & Transducers 4 to 8 oz.
Transducer Cable Lengths



With Connectors 2 ft., 6.5 ft. & 16 ft.
Notes:
1- When ambient temperature is 20 C;
2- When ambient temperature exceeds 50 C, E-220B series modules operating at 12 V DC input will require a 75 kOhm resistor between the TRIG INGND pins. Minimum sensing range will increase (move out) by approximay 5%. Please contact factory for additional information.



Ordering Information



Specify the part number which corresponds to both the model numbertransducer cable length desired. Specify the optional mounting bracket part number as listed for each model number.



Model Number
2 ft. Cable
6.5 ft. Cable
16 ft. cable
Mounting Bracket

E-201B/215
200344-501
200344-502
200344-503
200359-1

E-201B/150
200343-501
200343-502
200343-503
200362-1



E-220B/215
200374-501
200374-502
200374-503
200358-3

E-220B/150
200373-501
200373-502
200373-503
200358-2

E-220B/40
200355-502
200355-505
200355-506
200358-1

E-220B/26
200355-501
200355-503
200355-504
200358-1



Functional Block Diagrams

Timing Diagram


Circuit Connections

Physical Dimensions
Mounting Brackets

Transducers

Electronics

 
產品圖片
 

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
在線留言
主站蜘蛛池模板: 通山县| 大方县| 靖安县| 宁远县| 夹江县| 曲麻莱县| 思茅市| 泸定县| 三江| 抚州市| 南乐县| 通许县| 繁峙县| 重庆市| 宿松县| 通榆县| 铜川市| 克什克腾旗| 洪江市| 维西| 六盘水市| 高阳县| 康平县| 晋江市| 苏尼特右旗| 伽师县| 平利县| 抚松县| 通海县| 杭锦旗| 临邑县| 海安县| 公安县| 奉贤区| 鄂托克前旗| 卫辉市| 咸阳市| 吉隆县| 腾冲县| 宁南县| 安义县|