GSTH-1420GSTH-1100GRTHO-1420GRTHO-1420Pt100GRTHO-1420Pt1000GRTHO-1420N3K室內用溫濕度變送器ROOMTEMP

詳細介紹

 

 

GSTH-1420 GSTH-1100 GRTHO-1420 GRTHO-1420Pt100 GRTHO-1420Pt1000 GRTHO-1420N3K室內用溫濕度變送器 ROOM TEMP./HUMI. TRANSMITTER

 

ROOM TEMP./HUMI. TRANSMITTER(GSTH-1420)
"GSTH" Room Temperature Humidity Transmitter is intended for ventilation and air-handling units to detect Room temperature and relative humidity.
Especially, This unit is very suitable for use in pulp/textile/food warehouse, greenhouse, computer room, R&D room, indoor swimming pool, hospital, etc.
This unit can be used with all system equipments that can receive output signals 4-20mA DC of the detector.
Relative Humidity
1) This Transmitter senses relative humidity by chargeable humidity sensing element which varies electrical capacity depending on circumstantial relative humidity.
2) Electronic sensing circuit varies signal into 4 ~ 20mA DC ( within 0 ~ 99% relative humidity )
Temperature
This Transmitter senses temperature by sensing element of PT1000Ω which varies electrical resistance depending on sensing temperature.

SUPPLY VOLTAGE : 24V AC ± 20%
FREQUENCY : 50 or 60Hz
POWER CONSUMPTION : below 1VA
SENSING RANGE : -10 ~ +70℃ / 0 ~99%RH
HUMIDITY ELEMENT : Integrated Circuity 
ACCURACY ( at 20°C ) : at 20~90% Rh, ±3%Rh
OUTPUT SIGNAL : Pt100(Pt1000Ω) / 4 ~ 20mADC
SENSING TIME : About 20sec
AMBIENT TEMPERATURE : 1) On operation : -10 ~ +70℃
2) On storage & Transportation : -25 ~ +65°C
AMBIENT HUMIDITY : 1) On operation : below 95%Rh
WIRING : 2and 3wires, 1.0m㎡
WEIGHT : 0.06Kg
HOUSING : plastic case
PROTECTION CLASS : IP30

Engineering
1) In case of control : Preferably install on the wall of building or house and keep away from direct light,
Select a location approx 1.5M above the floor for the sensor which is representative of the space to be controlled and where it will be readily affected by changing in the general space temperature & humidity level.
The sensor location should also be reasonably clean and free damp and condensation.
ROOM TEMP./HUMI. TRANSMITTER(GSTH-1100)
"GSTH" Room Temperature Humidity Transmitter is intended for ventilation and air-handling units to detect Room temperature and relative humidity.
Especially, This unit is very suitable for using in pulp/textile/food warehouse, greenhouse, computer room, R&D room, indoor swimming pool, hospital, etc.
This unit can be used with all system equipments that can receive output signals 0 ~10V DC of the detector.
Relative Humidity
1)This Transmitter senses relative humidity by chargeable humidity sensing element
which varies electrical capacity depending on circumstantial relative humidity.
2)Electronic sensing circuit varies signal into 0 ~ 10V DC ( within 0 ~ 99% relative humidity )
Temperature
This Transmitter senses temperature by sensing element of PT1000Ω which varies electrical resistance depending on sensing temperature.

SUPPLY VOLTAGE : 24V AC/DC ± 20%
FREQUENCY : 50 or 60Hz
POWER CONSUMPTION : below 1VA
SENSING RANGE : -10 ~ +70℃ / 0 ~ 99% RH
HUMIDITY ELEMENT : Integrated Circuity
ACCURACY ( at 20°C ) : at 20~90% Rh, ±3%Rh
OUTPUT SIGNAL : Pt1000Ω(Pt100Ω) / 0 ~ 10VDC
SENSING TIME : Apprx 20sec
AMBIENT TEMPERATURE : 1) On operation : -10 ~ +70℃
2) On storage & Transportation : -25 ~ +65°C
AMBIENT HUMIDITY : 1) On Operation : below 95%Rh
WIRING : 2and 3wires, 1.0m㎡
WEIGHT : 0.06Kg
HOUSING : plastic case
PROTECTION CLASS : IP30

Select a location approx 1.5M above from the floor.
The sensor location should also be reasonably clean and free damp and condensation.
ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420Pt1000)
GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units. Also can be used interface detect transmitter with sensing value display or auto control system of building
Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
Use as measuring Transmitter : In case of optimistic function system.
SUPPLY VOLTAGE : DC 15~30V  
OUTPUT SIGNAL : Temperature / Pt1000Ω, Humidity / 4 ~ 20mA
SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
SENSING ELEMENT : Integrated Circuity, PT1000
TEMPERATURE CO-EFFICIENT : 0.00385 OHMS
SELF-GENERATING CURRENT : below 2mA ( 0.02 OHM / 0.05 Deg.)
ACCURACY : at 25°C within ±0.3°C / ±3% RH at 10 ~ 90%RH
WIRING : 4 Wire
SENSING TIME : within 1 minute apprx.
AMBIENT TEMPERATURE
1) On Operation : -10 ~ +70°C
2) On Transportation & storage : -15 ~ +50°C
AMBIENT HUMIDITY
1) On Operation : below 95%Rh
PROTECTION CLASS ENCLOSURE : IP30 (EN60529)
WEIGHT : 0.10 Kg
Engineering
In case of control : Preferably install on the wall of house or building, and keep away from direct light.
1) Installation height : Preferably install in the middle of house, building or heating area.
and to be installed at least 1.5 meter above from the floor.
2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted.
ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420N3K)
“ GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units. Also can be used interface detect transmitter with sensing value display or auto control system of building.
Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
Use as measuring Transmitter : In case of optimistic function system .
SUPPLY VOLTAGE : 15~30VDC
OUTPUT SIGNAL : Temperature / NTC 3KΩ, Humidity / 4 ~ 20mA
SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
SENSING ELEMENT : Integrated Circuity, NTC Ω
SELF-GENERATING CURRENT : below 2mA
ACCURACY : at 20°C within ±3%RH ( humidity )
WIRING : 4 Wire
SENSING TIME : within 1 minute apprx.
AMBIENT TEMPERATURE
1) On Operation : -10 ~ +70°C
2) On Transportation & storage : -15 ~ +60°C
AMBIENT HUMIDITY
1) On Operation : below 99%Rh
2) On Transportation & storage : below 95%Rh
PROTECTION CLASS : IP30 (EN60529)
WEIGHT : 0.10 Kg
Engineering
In case of control : Preferably install on the wall of house or building, and keep away from direct light.
1) Installation height : Preferably install in the middle of house, building or heating area.
and to be installed at least 1.5 meter above from the floor.
2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted
ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420)
ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420Pt100)
"GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units.
Also can be used interface detect transmitter with sensing value display or auto control system of building.
Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
Use as measuring Transmitter : In case of optimistic function system
SUPPLY VOLTAGE : DC 15~30V +20%
OUTPUT SIGNAL : Temperature / Pt100Ω, Humidity / 4 ~ 20mA
SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
SENSING ELEMENT : Integrated Circuity, PT100
TEMPERATURE CO-EFFICIENT : 0.00385 OHMS
SELF-GENERATING CURRENT : below 2mA
ACCURACY : at 25°C within ±0.3°C / ±3% RH at 10-90%RH
WIRING : 4 Wire
SENSING TIME : within 1 minute apprx
AMBIENT TEMPERATURE
1) On Operation : -10 ~ +70°C
2) On Transportation & storage : -15 ~ +50°C
AMBIENT HUMIDITY
1) On Operation : below 95%Rh
PROTECTION CLASS : IP30 (EN60529)
WEIGHT : 0.10 Kg
Engineering
1) In case of control : Preferably install on the wall of house or building, and keep away from direct light.
1) Installation height : Preferably install in the middle of house, building or heating area.
and to be installed at least 1.5 meter above from the floor.
2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted.

“ GOTHO “ Outside Air temperature & Humidity Transmitter is intended for controlling Sensor by detecting relative humidity and temperature of outside air for ventilation and air-handling units. This unit can also be used as Interface detector used with display
of sensing value or Auto control system of building

Pulp/Textile warehouse, Greenhouse, Computer room, R&D room, Hospital, etc.
Use measuring detector : In case of Optimistic function system

SUPPLY VOLTAGE

: 15 ~ 30V DC

OUTPUT SIGNAL

: 4 ~ 20 mA

SENSING RANGE

: Temperature /-20 ~ +50°C,
  Humidity / 0 ~ 99%RH

SENSING ELEMENT

: Pt 1000Ω / Integrated Circuity

SELF-GENERATING CURRENT

: below 2mA ( 0.02 OHM / 0.05 Deg.)

ACCURACY

: at 20°C within ±0.3°C,
  at 10 ~ 90%RH, ±3%RH

WIRING

: 4 Wire

SENSING TIME

: 1 minute apprx.

AMBIENT TEMPERATURE

: 1) On Operation : -30 ~ +70°C
  2) On Transportation & Storage : -20 ~ +50°C

AMBIENT HUMIDITY

: 1) On Operation : below 99%Rh
  2) On Transportation & Storage : below 95%Rh

PROTECTION CLASS

: IP30 (EN60529)

WEIGHT

: 0.10 Kg

Engineering
1) In case of control : Preferably install on the wall of building or house and keep away from direct light.

1) Installation height ; Preferably install in the middle of house, building or heating area, and to be installed at least 1.5 meter above from the floor.
2) Prohibited Location ; Window, door, Ventilating hole, upper place of heat source, and Veranda or beneath the eaves of roof.
3) To prevent any detecting errors from convection of warm air, cable wire tube of transmitter should be shielded and must not be painted
ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420N3K)
“ GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units. Also can be used interface detect transmitter with sensing value display or auto control system of building.
Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
Use as measuring Transmitter : In case of optimistic function system .
SUPPLY VOLTAGE : 15~30VDC
OUTPUT SIGNAL : Temperature / NTC 3KΩ, Humidity / 4 ~ 20mA
SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
SENSING ELEMENT : Integrated Circuity, NTC Ω
SELF-GENERATING CURRENT : below 2mA
ACCURACY : at 20°C within ±3%RH ( humidity )
WIRING : 4 Wire
SENSING TIME : within 1 minute apprx.
AMBIENT TEMPERATURE
1) On Operation : -10 ~ +70°C
2) On Transportation & storage : -15 ~ +60°C
AMBIENT HUMIDITY
1) On Operation : below 99%Rh
2) On Transportation & storage : below 95%Rh
PROTECTION CLASS : IP30 (EN60529)
WEIGHT : 0.10 Kg
Engineering
In case of control : Preferably install on the wall of house or building, and keep away from direct light.
1) Installation height : Preferably install in the middle of house, building or heating area.
and to be installed at least 1.5 meter above from the floor.
2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted

關鍵詞:溫濕度變送器

感興趣的產品PRODUCTS YOU ARE INTERESTED IN

智能制造網 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.xashilian.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,智能制造網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
主站蜘蛛池模板: 三河市| 乌拉特前旗| 江西省| 玉山县| 通辽市| 南皮县| 乐陵市| 广西| 利川市| 霸州市| 来安县| 若尔盖县| 固始县| 六枝特区| 涞源县| 丹东市| 三门峡市| 昆明市| 正安县| 和田县| 武乡县| 新沂市| 光泽县| 济源市| 长汀县| 建昌县| 宿松县| 郓城县| 新田县| 从化市| 渑池县| 湖南省| 肥西县| 塔城市| 博乐市| 论坛| 阿坝| 谢通门县| 会宁县| 基隆市| 深泽县|