橫河AAT145-S03輸入模塊
TC Input/RTD Input Module (Isolated Channels)
These modules receive signals from mV, thermocouple (TC), RTD, and potentiometer (POT). These are isolated between the ?eld and the system as well as between each channel.
They can be used in dual redundant con?guration.
These two modules can be used in dual redundant con?guration.
Items | Speci?cations | ||
Model | AAT145 | AAR145 | |
Number of input channels | 16, isolated channels | 16, isolated channels | |
Input signal |
TC: JIS C1602:1995 (*1), IEC584:1995 Type J, K, E, B (*2), R, S, T, N mV: -100 to 150 mV, -20 to 80 mV | RTD: JIS C1604:1997 (*3), IEC751:1995 Pt100 (3-wire type) POT: Total resistance 100 Ω to 10 kΩ Span resistance: 50 % or more of total resistance | |
Switching input signals |
TC/mV can be set individually for CH1 to CH16. | RTD/POT can be selected individually for CH1 to CH16. | |
Allowable input voltage | ±5 V | ±5 V | |
Withstanding voltage | Between input and system: 500 V AC (for single card: 1500 V AC), For 1 minute Between input channels: 200 V AC, For 1 minute | ||
Input resistance | Power ON | 1 MΩ or more | |
Power OFF | 1 MΩ or more | ||
Accuracy |
±40 µV | RTD: ±150 mΩ POT: ±0.2 %/FS | |
Allowable total resistance of signal source plus wiring |
1000 Ω or less |
150 Ω or less (wiring resistance per wire)(*4) | |
Effect of allowable signal source resistance (1000 Ω) |
±20 µV |
— | |
Reference junction compensation accuracy |
±1 °C (*5) (6) |
— | |
Measurement current | — | RTD: 1 mA | |
Data update period | 1 s | ||
Burn-out | All channels can be set together. Setting: not available/available (UP/DOWN) detection time: 60 s | ||
Temperature drift |
±80 µV/10 °C | RTD: ±0.3 Ω/10 °C POT: ±0.4 %/10 °C | |
Maximum current consumption |
350 mA (5 V DC) |
350 mA (5 V DC) | |
Weight | 0.3 kg | ||
External connection | Dedicated cable (KS1) | Dedicated cable (KS8/AKB335) |
*1: Model AAT145 is also in compliance with JIS C1602:1981.
*2: Type B dose not carry out temperature compensation and can not measure under 44 °C.
*3: Model AAR145 is also in compliance with JIS C1604:1989 (Pt100, JPt100).
*4: Wiring resistance for the signal cables of IN£A and IN£B must be identical.
*5: This accuracy changes due to the installation condition.
橫河電機集團已于6月12日發布公司旗艦產品——綜合生產控制系統CENTUM? VP的功能強化版CENTUM? VP R5.03。
CENTUM VP作為IA業務運行的VigilantPlant?(理想的工廠)理念的基礎,橫河電機在不斷地對其進行開發和強化。根據2015中期經營計劃中制定的策略,CENTUM VP增加了多種新功能。
CENTUM? VP綜合生產控制系統
新特點包括:
通過公用通信網絡實現廣域通信(WAC)路由器控制
橫河電機開發了WAC路由器,這樣,CENTUM VP系統就能在通過公用通信線路、衛星鏈路等建立的廣域網絡(WAN)中實現設備的遠程監視和控制。WAC路由器與橫河電機生產控制系統中使用的
Vnet/IP控制網絡具有相同的高可靠性和安全性。它根據數據類型和目標,優化通信,從而對有限的帶寬和傳輸延遲進行補償。為了實現更高的可靠性,路由器具有雙冗余通信模塊。每個模塊可通過zui多兩條通信線路與WAN連接。當采用兩條線路時,AAT145-S03線路可以是相同類型的,也可以是不同類型的,如衛星鏈路和光纖電纜。對于廣域分布的設備,如油氣勘探和生產中使用的海上平臺,路由器能實現可靠、低成本的監視和控制。
增強的批處理功能
CENTUM VP R5.03批處理軟件包*1以ISA-88為基礎,功能得以強化,能夠更加靈活的應對生產工序的變化。操作程序的數量得到了增加,配方*2程序也可以進行更加詳細的定義,從而簡化了更
改配方的過程。因此,CENTUM VP R5.03是具有復雜批量生產工藝的公司和從事食品加工、制藥及化學品等行業的公司的理想選擇。
*1 批處理軟件包
在使用相同的設備和裝置生產多種產品的批處理工藝中使用。
*2 配方
批處理工藝配方規定特定產品的制造工藝,對設備、配方和工序等項目的要求。
易于與智能電氣設備(IED)集成
CENTUM VP R5.03支持IEC 61850通信協議,該協議在電力行業及其他大量操作電氣設備的行業中被廣泛采用。版CENTUM VP能集成智能電氣設備中的數據,可用于監測電廠中根據IEC
61850標準設計的電氣設備的運行狀況。這可以更好地與電廠運行進行集成,也能夠監測其他多種類型工廠中的電氣設備。
八回路操作鍵盤
新發布的鍵盤具有功能鍵,可用于同時調節八個控制回路。對于圖像、報警和趨勢操作,也有控制鍵、操作確認鍵、窗口打開鍵等共64個功能鍵,還有報警確認和按鍵鎖定鍵。
這種鍵盤的設計能使工廠操作員更輕松地執行任務。
主要目標市場
多種行業的過程控制和監視應用,如石油天然氣、石化、化工、電力、造紙、制藥、食品加工、鋼鐵、供水以及水處理等行業。
應用
控制并監視工廠和生產設備
未來的發展
橫河電機把CENTUM VP作為核心平臺,會繼續開發更多的生產控制系統。橫河電機立足于2015中期經營計劃,正在強化目標市場的綜合解決方案。
關于VigilantPlant?
VigilantPlant?是橫河電機對于安全、可靠和有效工廠運行的一個概念總結。旨在實現運行的可持續發展狀態,工廠的員工保持警惕,注意力集中,信息獲取及時,并且隨時準備采取行
動,從而優化工廠和業務的績效。基于這個理念,橫河電機推出了多種多樣的安全、資產、生產,以及生命周期的解決方案。