Preparing chemically competent cells
Materials
- Plate of cells to be made competent
- TSS buffer
- LB media
- Ice
Glassware & Equipment
- Falcon tubes
- 500μl Eppendorf tubes, on ice
- 200ml conical flask
- 200μl pipetman or repeating pipettor
- 5ml pipette
Preparation
- Grow a 5ml overnight culture of cells in LB media. In the morning, dilute this culture back into 25-50ml of fresh LB media in a 200ml conical flask. You should aim to dilute the overnight culture by at least 1/100.
- Grow the diluted culture to an OD600 of 0.2 - 0.5. (You will get a very small pellet if you grow 25ml to OD600 0.2)
- Put eppendorf tubes on ice now so that they are cold when cells are aliquoted into them later. If your culture is X ml, you will need X tubes. At this point you should also make sure that your TSS is being chilled (it should be stored at 4oC but if you have just made it fresh then put it in an ice bath).
- Split the culture into two 50ml falcon tubes and incubate on ice for 10 min.
All subsequent steps should be carried out at 4oC and the cells should be kept on ice wherever possible
- Centrifuge for 10 minutes at 3000 rpm and 4oC.
- Remove supernatant. The cell pellets should be sufficiently solid that you can just pour off the supernatant if you are careful. Pipette out any remaining media.
- Resuspend in chilled TSS buffer. The volume of TSS to use is 10% of the culture volume that you spun down. You may need to vortex gently to fully resuspend the culture, keep an eye out for small cell aggregates even after the pellet is compley off the wall.
- Add 100 μl aliquots to your chilled eppendorfs and store at − 80oC.
- The original paper [1] suggests freezing the cells immediay using a dry ice bath. I (BC) have used liquid nitrogen quite successfully instead of dry ice. Simply placing the cells at − 80oC also seems to work well (Jkm)
- If you run a control every time you clone (i.e. a vector-only ligation), you can as well freeze cells in 200 μl aliquots. Unused cells can be frozen back once and reused, albeit with some loss of competence.
- It is a good idea to run a positive control on the cells.
- The Endy Lab is trying to use a standard positive control to better compare (and hopefully improve) the transformation efficiencies in the lab, you can check it out here.
下一篇:色牢度檢測標準介紹
免責聲明
- 凡本網注明"來源:智能制造網"的所有作品,版權均屬于智能制造網,轉載請必須注明智能制造網,http://www.xashilian.com。違反者本網將追究相關法律責任。
- 企業發布的公司新聞、技術文章、資料下載等內容,如涉及侵權、違規遭投訴的,一律由發布企業自行承擔責任,本網有權刪除內容并追溯責任。
- 本網轉載并注明自其它來源的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點或證實其內容的真實性,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品來源,并自負版權等法律責任。
- 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。
2025長三角國際智能儀表/線纜產業博覽會
展會城市:滁州市展會時間:2025-11-11